Dynamic Operation - Siemens SIMODRIVE 611 digital Configuration Manual

Drive converters
Hide thumbs Also See for SIMODRIVE 611 digital:
Table of Contents

Advertisement

1 Overview of the Drive System
1.3 Engineering a drive
1.3.2

Dynamic operation

1-32
www.aotewell.com
The peak infeed power must also be calculated for acceleration and decelera-
tion operations.
S
Feed axes
The peak infeed power expected for feed axes can be roughly calculated
according to the following formula:
P
= 0.6 V
S FD
Where:
P
peak infeed power (calculated) [kW] for feed axes
S FD
0.6
empirical factor: DC link energy and
and EMF of the motor are taken into account
V
DC link voltage [V] (600 V)
DC link
I
peak current [A] set for an axis
max
ñ/n
max. axis speed referred to the
N
motor rated speed
S
Feed axes with linear motors
P
= F
S FD
= 0.5 ... 0.9 ⋅ U
Where:
F
maximum force [N]
MAX
V
maximum velocity at the maximum force [m/min]
MAX, FMAX
I
peak current [A] set for an axis
max
I
rated current [A] set for an axis
N
P
rated motor power loss [kW]
VN
~
v/V
max. axis velocity referred to the maximum velocity at the
MAX, FMAX
maximum force
S
Main spindles
The peak infeed power expected for main spindles is calculated according
to the following formula:
– Motors
v 4 kW
= 1.45 ⋅ P
P
S MSD
– Motors
> 4 kW
= 1.25 ⋅ P
P
S MSD
Where:
P
peak power (calculated) for main spindles [kW]
S MSD
1.25 or 1.45
factor to take into account the motor efficiency
P
peak power [kW] used at the shaft of the
S motor shaft MSD
main spindle motor
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
sales@aotewell.com
⋅ I
⋅ ñ/n
⋅ 10
DC link
max
N
⋅ V
+ (I
/I
MAX
MAX, FMAX
MAX
~
⋅ I
⋅ v/V
ZK
MAX
MAX, FMAX
[kW]
S motor shaft MSD
[kW]
S motor shaft MSD
© Siemens AG 2008 All Rights Reserved
Industry Automation
10.04
05.01
–3
[kW]
2
)
⋅ P
[kW]
N
VN
–3
⋅ 10
[kW]
+86-755-8660-6182