6 Infeed Modules

6.2 Function overview and settings

6.2
Function overview and settings
General
information
Switch S1.1
6-154
www.aotewell.com
A switch S1 is provided on the upper side of the NE and monitoring module that
is used to set the following functions (for UI 5 kW on the front side):
ON:
V
= 415 V10% V
= 625 V
line
DC link
Error message
Regenerative feedback into the
line supply off
+
2)
V
= 480 V
6% - - 10%
line
Controlled infeed off
Sinusoidal current operation µ
(on the line side)
Standard setting
1) Only possible for I/R modules - - for all
NE modules, the monitoring thresholds are increased (2.5%).
2) For S1.4 = ON, S1.1, S1.3 and S1.6 have no effect.
Fig. 6-5
DIL switch S1
Note
For a configuration 480 V S1.4= ON, only controlled regenerative feedback is
realized, independent of the position of S1.5.
Notice
For I/R modules, sinusoidal current mode is the initial setting.
For operation with filters that are not listed in Table 6-1, the mode must be
changed to squarewave current mode in order to protect the filter from thermal
overload.
Before powering up or down using the main switch or a line contactor, terminal
63 (pulse enable) and/or terminal 48 (start terminal, contactor control) must be
de--energized!
OFF: I/R module
U
UI module
V
Monitoring thresholds: (I/R, UI, monitoring modules)
PR on = 644 V;
PR off = 618 V 2.5%
V
≥ 695 V 2.5%
DC link
ON:
I/R module
V
UI module
V
Monitoring thresholds: (I/R, UI, monitoring modules)
PR on = 670 V 2.5%;
V
≥ 710 V 2.5%
DC link
PR = Pulsed resistor
SIMODRIVE 611 Configuration Manual (PJU) - - 05/2008 Edition
sales@aotewell.com
S1
OFF:
1
1)
V
= 400 V10% V
line
2
Ready signal
Regenerative feedback into the
3
line supply on
4
Standard, refer to switch S1.1
5
Controlled infeed
Squarewave current operation
6
(on the line side)
3- -ph. 400 V AC
3- -ph. 415 V AC
ON 1
ON 1
.
S1.1
.
S1.4
4
= 400 V 10%; V
line
DC link
= 400 V 10%; V
line
DC link
= 415 V 10%; V
line
DC link
= 415 V (440 V) 10%; V
line
PR off = 640 V 2.5%
© Siemens AG 2008 All Rights Reserved
Industry Automation
05.08
11.05
05.01
1)
= 600 V
DC link
3- -ph. 480 V AC
ON 1
.
.
.
.
4
4
= 600 V 2.5%
= V
¯ 1.35
line
= 625 V 2.5%
= V
¯ 1.35
DC link