Wiring

The SINUMERIK 840D and the HLA module are supplied from the
SIMODRIVE line supply infeed or from the SIMODRIVE monitoring module via
the equipment bus. There must be at least one NE module in the equipment
group when an HLA module is used. No provision has been made for any other
type of voltage supply and failure to use the supply provided could damage the
unit.
Note
It is not permissible to operate an HLA module on its own with a SIMODRIVE
monitoring module!
Power is supplied to downstream electrical axes via the DC link busbars (40
2
mm
) of the carrier module.
One position encoder for each axis can be evaluated on the HLA module.
S
X101:
S
X102:
The measuring system must always be plugged into the connector of the asso-
ciated axis.
Table 5-18
Pin
X101
1
PENC0
2
M
3
AP0
4
AN0
5
ENDATDAT0
6
BP0
7
BN0
8
XENDATDAT0 XENDATDAT2 Inverse EnDat or
9
PSENSE0
10
RP0
11
MSENSE0
12
RN0
13
M
14
ENDATCLK0
15
XBMICLK0
Note: The SSI encoder requires an external 24 V power supply
1)
The permissible voltage range for the common mode component of the
individual encoder signals (AP. AN. BP, BP, RP, RP) is 1.5...3.5 V.
sales@aotewell.com
5.4 "HLA module" control board
Axis 1
Axis 2
Connectors X101, X102; 15–pin sub–D plug connector (two–tier)
1)
1)
X102
PENC2
Encoder power supply
M
Encoder power supply ground
AP2
Incremental signal for track A
AN2
Inverse incremental signal for track A
ENDATDAT2
EnDat or SSI interface data signal
BP2
Incremental signal for track B
BN2
Inverse incremental signal for track B
SSI interface data signal
PSENSE2
Remote sense encoder power supply (P)
RP2
Zero pulse/reference mark signal A
MSENSE2
Remote sense encoder power supply (M)
RN2
Inverse zero pulse/reference mark signal A
M
Ground (for internal shields)
ENDATCLK2
EnDat or SSI interface clock signal
XBMICLK2
Inverse EnDat interface clock signal