Input enable
5.5.3
Drive bus
Equipment bus
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
HongKong|UK|China
www.aotewell.com
Caution
!
The +24 V outputs for shut–off valves for axes 1 and 2 are short–circuit proof.
The energy absorbed when inductive loads are disconnected must be limited to
1.7 J by the user. When the supply polarity is reversed, the outputs are not
protected against overload.
The module–specific enable is realized using terminal 663. The input is evalu-
ated via the optocoupler in the ANA module. The enable voltage can be taken
from terminal 9.
Terminal 663 is referenced to the internal enable voltage (ground, terminal 19).

Bus interfaces

(refer to SIMODRIVE 611 digital)
S
X141:
S
X341:
A bus terminator must be plugged into the last module.
(refer to SIMODRIVE 611 digital)
S
X151:
sales@aotewell.com
5.5 "ANA module" control board
Input
Output
Equipment bus
Industry Automation
5 Control Units
J
5-147