4 Power Modules
4.4 Current reduction/derating
4.4.2
Temperature–dependent derating
110
105
100
95
90
85
80
75
70
65
60
55
50
45
40
30.0
Fig. 4-8
Power as a function of the temperature
4.4.3
Installation height–dependent derating
110
105
100
95
90
85
80
75
70
65
60
55
50
45
40
0
500
Fig. 4-9
Power relative to the installation altitude
4-92
www.aotewell.com
For an ambient temperature T > 40 °C, derating is required according to the
following rule:
X
=100% – 2.5% (T
TU
U
35.0
40.0
Notice
The maximum ambient temperature for operation of T
exceeded.
For an installation altitude h > 1000 m above sea level, derating is required ac-
cording to the following derating characteristic:
1000
1500
2000
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
sales@aotewell.com
– 40 °C)
45.0
Ambient temperature in °C
2500
3000
3500
4000
Installation altitude above sea level in m