6 Infeed Modules

6.6 Monitoring module

6.6
Monitoring module
6.6.1
Integration into the overall system
6.6.2
Technical data (supplement to the general technical data)
1) Up to version "B", we recommend that at least two control units are connected to a monitoring module.
6-176
www.aotewell.com
The monitoring module includes the electronics power supply and the central
monitoring functions that are required in order to operate the drive modules.
A monitoring module is required if the power supply rating of the NE module is
not sufficient for the drive group.
Table 6-12
Technical data, monitoring module
Power loss
Rated supply voltage
Alternatively, rated supply voltage
DC link
Current consumption
Type of cooling
Weight
Assessment factor for the electronic points
(EP)
Assessment factor for the gating points (AP)
The cross–section that can be connected to
the P600, N600, X131 terminal block
Reader's note
For an overview of the interfaces, refer to Section 6.5.1, Table 6-10 in the
column "Terminals used" under monitoring module.
For operation of the monitoring module only on the DC link, without AC power
supply, 1000 µF per monitoring module must be observed for the loading limit of
the line supply.
This capacity is not included in the calculation of the permitted number of
pulsed resistors, because they are de–coupled using diodes.
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
sales@aotewell.com
1)
70 W
3–ph. 400 V – 10% up to 480 V AC +
6%
600/625/680 V DC
for 3–ph. 400 V AC: approx. 600 mA
Natural ventilation
approx. 5 kg
Max. 8
Max. 17
S
Max 10 mm
conductor end sleeves
S
Max 16 mm
pin–type cable lug
© Siemens AG 2008 All Rights Reserved
Industry Automation
05.08
11.05
05.01
2
for cables with
2
for cables with
+86-755-8660-6182

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents