Cleaning - TCS IVW3012-0110 Product Information

Video indoor stations color skyline surface/flush-mount
Table of Contents

Advertisement

07/2012
Multiple contours occur.
Contours of the second image
are visible.
No image. Image switch button
does not respond when press-
ing.
The video image turns white
after a while. When switching
the supply voltage off and on
again, the signal will reappear.
After a while, the video image
turns white again.
Avoid water entering the device!
!
Do not use any abrasive detergents!
Clean the device with a dry or slightly moist cloth.
Remove stronger stains with a mild plastic cleaner.
TCS TürControlSysteme AG
E-Mail: hotline@tcsag.de • www.tcsag.de
31
Image reflections, so called "ghost
images" occur due to open lines.
Two video sources interfere.
No signal present.
Not both wires of the video BUS
are connected.
Thermal defect of the outdoor
cam-era.

Cleaning

The video strand is not closed.
Please insert the terminating re-
sistor at the last device of the
strand.
Please remove the second video
source from the strand.
If necessary, connect this second
video source via a video switch to
the existing TCS:BUS.
Connect the monitor in front of the
video switch and check whether a
signal is available here.
Measure the voltage between P and
b.
The voltage usually is about 24 V.
If this is not the case, please check
the power supply of the BUS.
Please check the connection of the
video connector in the video module
of the IMM.
Die V1-Ader des Video-Busses hat
einen Schluss auf die P- oder die
b-Ader. Dadurch fließt ein unzuläs-
sig erhöhter Strom.
Bitte die Verkabelung auf Schlüsse
überprüfen.
The camera is defect.
The camera FVK2200 (color variant
of VKM10) is defect. Around. 2% of
all cameras has this defect. Chang-
ing the camera corrects the prob-
lem.
Subject to technical changes.
PI_IVW3012_0x10_uk.doc