ISH3030-0140 UK 2 A
ISH3030

Advertisement

Table of Contents
loading

Summary of Contents for TCS ISH3030

  • Page 1 Product information Door telephone ISH3030 TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de ISH3030-0140 UK 2 A...
  • Page 2: Table Of Contents

    Connecting lines ....................... 9 Wiring diagram ......................... 9 Connection diagram 2-wire technique ................10 Connection diagram 3-wire technique ................10 Replacing an ISH1030 or TTS1 by an ISH3030 ............. 10 Commissioning ........................10 Settings ..........................10 Pre-adjusted times ......................10 2-wire/3-wire operation ....................
  • Page 3: Scope Of Delivery

    32 V DC is not exceeded at the connections a,b,P,E. Intended use  The ISH3030 are door telephones for the object area.  They are suitable for the operation in TCS audio systems and combined audio / video systems.  They are suitable for surface-mount.
  • Page 4: Max. Number Ish3030 In 3-Wire Operation

    07/2013 max. number ISH3030 in 3-wire operation in case of using power max. number supply and control unit ISH3030 BVS20 or NBV1000, 1 line BVS100, distributed on 3 lines PSG02, 1 Strang BVS20 + NGV1011, AS front-door station 1 line...
  • Page 5: Device Overview

    Degree of protection: IP30 Input current, standby 2-wire operation: I(a) = 1 mA 3-wire operation: I(a) = 0.2 mA, I(P) =0.8 mA Max. input current: I(Pmax) = 70 mA TCS TürControlSysteme AG Subject to technical changes. Mail: hotline@tcsag.de ISH3030-0140 UK...
  • Page 6: Short Description

    Position the flush-mounted socket below the cable conduit.  Install the lower cover with three screws. TIPP: Avoid tearing of the straps: For fixing the straps do not use counter-head screws or flat washers! TCS TürControlSysteme AG Subject to technical changes. Mail: hotline@tcsag.de ISH3030-0140 UK...
  • Page 7: Connecting The Lines (2-Wire Technique)

     Snap-in the upper cover below with slight pressure (2) Connect the handset  Put the western plug of the handset cord into the socket at the underside of the telephone. TCS TürControlSysteme AG Subject to technical changes. Mail: hotline@tcsag.de ISH3030-0140 UK...
  • Page 8: Open The Device

    FBI4200 FFS3100  The extended functions (and the antenna) have to be fixed with adhesive pads in the indoor station (see also product information of the corresponding extended function). TCS TürControlSysteme AG Subject to technical changes. Mail: hotline@tcsag.de ISH3030-0140 UK...
  • Page 9: Connecting The Lines

    2 x 0.8 mm, 3 x 0.6 mm Further wires have to be connected via auxiliar terminals! Use only connecting lines with the same diameter in one terminal contact. Wiring diagram TCS TürControlSysteme AG Subject to technical changes. Mail: hotline@tcsag.de ISH3030-0140 UK...
  • Page 10: Connection Diagram 2-Wire Technique

    Replacing an ISH1030 or TTS1 by an ISH3030  The floor push-button have to be connected always to the a-wire.  In case of a parallel circuit both telephones have to be replaced by the ISH3030. Commissioning  Install the devices of the system voltage-free and completely.
  • Page 11: 2-Wire/3-Wire Operation

    For selecting a second door ring tone it is necessary to activate the call distinction by changing the audio AS limit. Changing the audio AS limit is only possible with the configuration software configo™. TCS TürControlSysteme AG Subject to technical changes.
  • Page 12: Adjust The Volume

    Ser. No. =the serial number of the new indoor station, that should be configured ParSNo. =the serial number of the indoor station, to which the new configured indoor station is allocated TCS TürControlSysteme AG Subject to technical changes. Mail: hotline@tcsag.de...
  • Page 13: General To The Conduit In Tcs Audio Systems

    07/2013 General information on the conduit in TCS audio systems The conduit is determined by structural conditions and is only limited by ist length.  Note when selecting the cables: the loop re- sistance can amount max. 20 Ω (table) ...
  • Page 14: Repair

    EEPROM of the front-door station.  Ensure that the new indoor station is connected to the TCS:BUS and the mains voltage is switched on (the operation LED at the power supply and control unit is ON) and fur- ther, that the access to the flat is guaranteed during the programming.
  • Page 15: Cleaning

    Avoid water from entering the device! Do not use any abrasive detergents! Clean the device with a dry or slightly wet cloth. Remove stronger stains with a standard plastic cleaner. TCS TürControlSysteme AG Subject to technical changes. Mail: hotline@tcsag.de ISH3030-0140 UK...
  • Page 16: Conformity

     Please contact us: hotline@tcsag.de. Service Please send your questions and inquiries to hotline@tcsag.de headquarters TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, 39307 Genthin | Germany Tel.: +49 (0) 3933/879910, FAX: +49 (0) 3933/879911, www.tcsag.de TCS TürControlSysteme AG Subject to technical changes. Mail: hotline@tcsag.de...