Setting The Menus Internal Calls And Control Functions; Simple; On/Off; Enocean - TCS IVW3012-0110 Product Information

Video indoor stations color skyline surface/flush-mount
Table of Contents

Advertisement

symbol
meaning
navigation buttons RIGHT, LEFT, UP and DOWN can be used for control-
ling
only the navigation button RIGHT, LEFT can be used for controlling
only the navigation buttons UP, DOWN can be used for controlling
the menu button can be used to confirm
the function key can be used to abort
the navigation button DOWN can be pressed and hold for 4 sec

Setting the menus internal calls and control functions

Entries into the menus. These points can be entered with the configuration software
configo™ via a limited character set and also uploaded into the device.
Each entry of the control function menu can be processed in 3 different ways:

Simple

With each triggering the same control protocol is sent. There will be no indication for the
state of the device that is switched. The serial number and the control function number can
be configured as parameter. Thus, it is also possible to automatically generate the own
serial number of the video indoor station IVW3012.

ON/OFF

Two different control protocols with the same serial number are sent alternately. One con-
trol function number is assigned to switch-on and the other to switch-off. Via two different
symbols, which appear alternately in front of the list entry, the state, which is switched last,
can be seen. Both control function numbers and the serial number can be configured, if
required, the device-individual serial number can also be generated.

EnOcean

This function is realised identically to the IMM1100. Thus, an EnOcean radio interface
FBI4200 can be connected. It can also be used to display switching states, without influ-
encing it. When triggering the list entry, a control function with a configurable serial number
is sent. The control function number can be freely selected (0 to 200 possible). Independ-
ent from sending the protocol, receiving the control protocols with the configured serial
number causes a switch over between the states. As shown under b), this is displayed by
symbols in front of the list entry. Thereby, the control function numbers 01 and 03 generate
the state OFF and the numbers 02 and 04 the state ON.
TCS TürControlSysteme AG
E-Mail: hotline@tcsag.de • www.tcsag.de
18
Subject to technical changes.
PI_IVW3012_0x10_uk.doc
07/2012

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ivw3012-0210

Table of Contents