supply voltage:
housing: surface-mount/flush-mount-box: steel, powder-coated / zinc-coated
dimensions
housing:
mounting
weight
acceptable ambient temperature:
input current:
max. input current:
video mode
screen diagonale:
resolution:
video signalling:
Video 6-wire technique necessary!
Error pattern
The video image is black and
white.
The colors at the video monitor
of the indoor station are too
bright or the image in total is
too bright.
TCS TürControlSysteme AG
E-Mail: hotline@tcsag.de • www.tcsag.de

Technical data

front-plate:
surface-mount:
flush-mount:
surface-mount device: 2045 g
flush-mount device:
Possible causes
The color saturation control of the
indoor station is set to minimum.
The transmission level of the vid-
eo BUS is too low.
The light intensity of at least 10
lux is not reached. Thus, the
camera switches to black/white.
The color saturation control at the
station is set too high.
The brightness control of the sta-
tion is set too high.
The level of the video signal is too
high.
The terminating resistor at the
end of the strand is not plugged.
29
26 V DC ± 8 %
aluminium, anodised and acrylic glass
H 215 mm x W 280 mm x D 30 mm
H 215 mm x W 280 mm x D 34 mm
H 215 mm x W 280 mm x D 6 mm
1960 g
5 °C to 40 °C
I(a) = 0.4 mA, I(P) = 16 mA
I(Pmax) = 240 mA
TFT-Color-Modul
14.5 cm (5.7")
640 x 480 pixel, RGB
symmetrical, 1 Vss FBAS,

FAQ

Our suggested solution
Adjust the contrast resp. color satu-
ration control.
The transmission level can be read-
justed at many components of the
video BUS (e.g. FVY).
Please check it in the product in-
formation of the active transmission
components.
The camera modules of the front-
door stations are very photosensi-
tive. Please ensure a sufficient illu-
mination or use external cameras.
Turn down the color saturation con-
trol.
Turn down the color saturation con-
trol.
Turn down the level of the video
BUS (e.g. rotary switch at the board
of the camera). Is only working, if
the terminating resis-tance at the
station or active ex-tended functions
(e.g. FVY) is set correctly.
Please plug the terminating resis-
tor.
Subject to technical changes.