White Balance Operation; Simplified Rgb Design Firmware Block Diagram - Teledyne m640 User Manual

Genie nano series monochrome & color gige vision area scan
Hide thumbs Also See for m640:
Table of Contents

Advertisement

displaying color. Users should consider using professional monitors which have factory calibrated
fixed presets conforming to sRGB or AdobeRGB color spaces.

White Balance Operation

The Nano white balance control allow either manual settings for the RGB gain levels, or an
automatic algorithm executing periodically or on demand. Automatic mode operates under the
assumption of a color neutral scene, where an IR filter installed on the Nano camera is
recommended for most applications.
For Manual Adjustments
RGB values range from 1 to 4, in 0.01 increments.
Use BalanceRatioSelector to select the RGB gain to adjust and use BalanceRatio to change the
gain value.
The user selects one color to stay fixed at a gain of 1.00 (often green).
Adjust the gain for R & B to achieve the white balance desired.
For Automatic Adjustments
With either periodic or on demand modes, the Nano will determine the color to set to a gain of
1.00, and then adjust the other two color gains. The BalanceRatio feature will show gain settings at
higher precision than user set values.
Set BalanceWhiteAuto to Periodic or OnDemand.
The periodic mode will recalculate every 10ms, while the on demand mode requires the
execution of balanceWhiteAutoOnDemandCmd.
The user can override the automatic choice of the color referenced to a gain of zero via the
balanceRatioReference feature, but often the results look false colored.

Simplified RGB Design Firmware Block Diagram

Sensor Data
Defective Pixel
Replacement
Nano Series GigE Vision Camera
Bayer Decoder
Color Space
Converter and
Saturation
YCbCr
Control
User LUT
YCbCr422
YCbCr to RGB
Converter and
Packer
Y Packer
Color Output
Selector
Operational Reference • 111

Advertisement

Table of Contents
loading

Table of Contents