External Output AC Timing Characteristics

The graphic below defines the test conditions used to measure the Nano external output AC
characteristics, as detailed in the table that follows.
Output Common Power
Output
R
Load
Opto-coupled Output: AC Characteristics at an internal FPGA temperature of 83C
Note: All measurements subject to some rounding.
Output
Output
Common
Current
Power
8 mA
3V
16 mA
8 mA
5V
16 mA
21 mA
8 mA
12V
16 mA
24 mA
8 mA
24V
16 mA
24 mA
AC characteristics for optional models denoted by "G3-GM2... or G3-GC2..." part numbers is found
in addendum –
AC Characteristics: "1 input / 3 output"
196 • Technical Specifications
Control
Signal
100%
90%
Output
10%
R
t
µs)
load
d1 (
Test
Leading Delay
250 ohm
0.47
124 ohm
0.47
514 ohm
4.66
236 ohm
0.5
73 ohm
0.45
1.4K ohm
0.62
677 ohm
0.54
316 ohm
0.5
2.88K ohm
0.62
1.42K ohm
0.63
810 ohm
0.79
Output Control Signal
t
d1
t
rise
t
t
µs)
rise (
d2 (
Rise Time
Trailing Delay
2.9
4.7
2.6
7.0
4.4
2.0
4.8
3.5
2.1
4.7
4.9
Models.
Nano Series GigE Vision Camera
t
t
t
d2
t
fall
t
µs)
µs)
fall (
Fall Time
11.4
26.6
4.3
19.5
13.3
25.3
4.4
17.9
3.1
10.7
18.1
24.9
7.5
19.9
3.8
11.5
18.9
39.9
10.9
27.1
5.2
17.4