Input Signals Electrical Specifications; External Input Details; External Input Dc Characteristics - Teledyne m640 User Manual

Genie nano series monochrome & color gige vision area scan
Hide thumbs Also See for m640:
Table of Contents

Advertisement

Input Signals Electrical Specifications

External Inputs Block Diagram
Common Ground (pin 3)

External Input Details

Opto-coupled with internal current limit.
Single input trigger threshold level
(TTL standard: <0.8V=Logical LOW, >2.4V=Logical HIGH. See
Used as trigger acquisition event, counter or timestamp event, or integration control.
User programmable debounce time from 0 to 255µs in 1µs steps.
Source signal requirements:
Single-ended driver meeting TTL, 12V, or 24V standards (see table below)
If using a differential signal driver, only one input can be used due to the shared input
common (see details below)

External Input DC Characteristics

Operating Specification
Input Voltage
Input Current
Input logic Low
Input logic High
Absolute Maximum Range before Possible Device Failure
Absolute Ratings
Input Voltage
192 • Technical Specifications
Input 2 (pin 7)
Protection
Input 1 (pin 5)
Protection
Minimum
+3 V
7 mA
2.4 V
Minimum
–36 Volts
Current
Limiter
Current
Limiter
lineDetectionLevel
Maximum
+36 V
10.1 mA
0.8 V
Maximum
+36 Volts
Nano Series GigE Vision Camera
feature).