I/O Control Feature Descriptions - Teledyne m640 User Manual

Genie nano series monochrome & color gige vision area scan
Hide thumbs Also See for m640:
Table of Contents

Advertisement

I/O Control Feature Descriptions

The following table describes these features along with their view attribute and minimum camera
firmware version required. Additionally the Device Version column will indicate which parameter is
a member of the DALSA Features Naming Convention (indicated by DFNC), versus the GenICam
Standard Features Naming Convention (SFNC tag is not shown).
The Device Version number represents the camera software functional group, not a firmware
revision number. As Genie Nano capabilities evolve the device version tag will increase, therefore
identifying the supported function package. New features for a major device version release will be
indicated by
green text
Display Name
Trigger Selector
Single Frame Trigger(Start)
MultiFrame Trigger(Start)
AcquisitionStart
Trigger(Start)
Trigger Mode
Off
On
Trigger Frames Count
Software Trigger
Trigger Source
Line 1
Line 2
Software
Action 1
Action 2
Timestamp Modulo Event
Timer1End Event
80 • Operational Reference
for easy identification.
Feature & Values
TriggerSelector
FrameStart
FrameBurstStart
AcquisitionStart
TriggerMode
triggerFrameCount
TriggerSoftware
TriggerSource
Line1
Line2
Software
Action1
Action2
timestampModuloEvent
Timer1End
Description
Selects which type of trigger to configure with the
various Trigger features.
Selects a trigger starting the capture of a single
frame. Frame size is determined by image format
feature "Height".
Selects a trigger to capture multiple frames. The
number of frames is specified by the
"triggerFrameCount" feature.
Enables the selection of a trigger source that starts
the Acquisition of one or many frames. (Ver.1.05)
Controls the enable state of the selected trigger.
Off
The selected trigger is turned off.
On
The selected trigger is turned active.
Sets the total number of frames to acquire when a
valid trigger is received. This feature is available
when Trigger Selector = MultiFrame Trigger(Start).
Generate a software command internal trigger
immediately no matter what the TriggerSource
feature is set to.
Specifies the internal signal or physical input line to
use as the trigger source. The selected trigger
must have its TriggerMode set to ON.
See Input Signals Electrical Specifications.
Select Line 1 (and associated I/O control block) to
use as the external trigger source. See
LineSelector feature for complete list.
Select Line 2 (and associated I/O control block) to
use as the external trigger source. See
LineSelector feature for complete list.
The trigger command source is only generated by
software using the Trigger Software command.
Select the GigEVision Action Command 1 as the
internal trigger source. This is a broadcast
command that multiple devices can respond to
simultaneously.
Select the GigEVision Action Command 2 as the
internal trigger source. This is a broadcast
command that multiple devices can respond to
simultaneously.
Select the
timestamp modulo event
trigger source.
Select the TimerEnd Event as the internal trigger
source.
Device
Version
& View
Beginner
Beginner
DFNC
Beginner
Beginner
Beginner
(Ver.
1.03)
(Ver.
1.05)
as the internal
(Ver.
1.03)
Nano Series GigE Vision Camera
1.00
1.00
1.00
1.00
1.00

Advertisement

Table of Contents
loading

Table of Contents