B140/B246 SERIES SERVICE MODE

SC900: Miscellaneous

SC No.
900
D
Electrical total counter error
The total counter contains
something that is not a number.
901
D
Mechanical total counter error
The mechanical counter is not
connected.
910
D
External Controller Error 1
911
D
External Controller Error 2
912
D
External Controller Error 3
913
D
External Controller Error 4
914
D
External Controller Error 5
The external controller alerted
the machine about an error.
919
B
External Controller Error 6 B140/B246
While EAC (External Application
Converter), the conversion
module, was operating normally,
the receipt of a power line
interrupt signal from the FLUTE
serial driver was detected, or
BREAK signal from the other
station was detected.
920
B
Printer error 1
An internal application error was
detected and operation cannot
continue.
921
B
Printer error 2
When the application started,
the necessary font was not on
the SD card.
Symptom
4-72
Possible Cause
B140
• NVRAM incorrect type
• NVRAM defective
• NVRAM data scrambled
• Unexpected error from external source
• Mechanical total counter defective
• Mechanical total counter connector not
connected
B140/B246
• Please refer to the instructions for the
external controller.
• Power outage at the EFI controller
• EFI controller was rebooted
• Connection to EFI controller loose
B140
• Software defective; turn the machine
off/on, or change the controller firmware
• Insufficient memory
B140
• Font not on the SC card