Ricoh MT-C1 Service Manual page 516

Table of Contents

Advertisement

15 February 2006
2906*
TD Sensor Control Voltage and Check
001
TD Sensor Control Voltage Setting
Adjustment mode for production. DFU
[4.0~12.0/0.1]
002
Automatic Adjustment Setting
Displays the TD sensor data stored when SP2801 (TD Sensor Initial Settings) is
executed.
2909*
Main Scan Magnification
001
Copy
Adjusts magnification in the main scan direction for copying.
[–2.0~+2.0/0.1%]
002
Printer
Adjusts magnification in the main scan direction for printing from a computer.
[–2.0~+2.0/0.1%]
2910*
Sub Scan Magnification
Adjusts magnification in the main scan direction for copying.
[–1.0~+1.0/0.1%]
2912*
Drum Reverse Rotation
001
Rotation Amount
Sets the length of time the drum is reversed to clean the drum cleaning blade.
[1~3/1]
To calculate the actual time of reverse rotation, multiply the selected value by the
15 ms.
002
Rotation Interval
Determines the frequency of drum reverse rotation for blade cleaning.
[0~6/1 min.]
2913*
Temperature & Humidity Display
001
Machine Temperature
002
Machine Humidity
2920*
LD Off Check
Checks if the LD turns off or on when the front door is opened. DFU
[0~1/1]
0: On
1: Off
SERVICE PROGRAM MODE TABLES
Shows the internal temperature of the machine.
Shows the internal humidity of the machine.
5-43