5. PARAMETERS

5.1.1 Parameter list

No.
Symbol
PA01
**STY
Control mode
PA02
**REG
Regenerative option
PA03
*ABS
Absolute position detection system
PA04
*AOP1
Function selection A-1
PA05
For manufacturer setting
PA06
PA07
PA08
ATU
Auto tuning
PA09
RSP
Auto tuning response
PA10
INP
In-position range
PA11
For manufacturer setting
PA12
PA13
PA14
*POL
Rotation direction selection
PA15
*ENR
Encoder output pulses
PA16
*ENR2
Encoder output pulses
PA17
For manufacturer setting
PA18
PA19
*BLK
Parameter write inhibit
Name
5 - 2
Initial value
Unit
0000h
0000h
Chapter 5 of the MR-J3- B
Servo Amplifier Instruction
0000h
0000h
Chapter 5 of the MR-J3- B
Servo Amplifier Instruction
0
1
1
0001h
Chapter 5 of the MR-J3- B
Servo Amplifier Instruction
12
100
pulse
1000.0
%
1000.0
%
0000h
0
Chapter 5 of the MR-J3- B
Servo Amplifier Instruction
4000
pulse/rev
0
0000h
0000h
000Fh
Chapter 5 of the MR-J3- B
Servo Amplifier Instruction
Reference
Section 5.1.3
Manual
Section 5.1.4
Manual
Manual
Section 5.1.5
Manual
Section 5.1.6
Manual