System Version 2 (Type Bw/Ww) - Viessmann Vitocal 300-G BW Installation And Service Instructions Manual

Compact heat pump with electric drive
Table of Contents

Advertisement

System version 1 (type BW/WW)
Parameter
Basic settings
System diagram
Wtimer DHW Circ. (e.g. DHW
circulation pump)
natural cooling (NC) in heating circuit A1
Remote control
Cooling
Cooling circuit
Electric heater
Inst.htg.water heat

System version 2 (type BW/WW)

Select system diagram 4 (see page 131)
■ 1 heating circuit with mixer (M2)
■ DHW heating with DHW cylinder
■ Heating water buffer cylinder
■ active cooling/natural cooling in a separate cooling circuit
Note
The hydraulic scheme is shown with heat pump type BW.
For type BWC, primary pump, secondary pump and three-way valve are already
integrated and connected within the appliance.
(cont.)
Setting
ID
2
Switching times,
setting
Yes
2
1
Yes
Preparing for installation
Parameter group
7000 System definition
701B System definition
2003 Heating circ. 1
7100 Cooling
7101 Cooling
7900 Electric heater
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitocal 300-g bwcVitocal 300-gwwVitocal 300-g wwc

Table of Contents