Preparing for installation
General information regarding the electrical connection
■ The total output of all connected appli-
ances must not exceed 1000 W. If the
total output ≤ 1000 W, the individual
rating of a component can be greater
than specified.
■ If two components are connected to
the same terminal, press both cores
together into a single wire ferrule.
■ If the compressor and/or the instanta-
neous heating water heater are oper-
ated at a lower tariff (power-OFF), pro-
vide an additional cable for the switch-
ing contact "power-OFF" (e.g. NYM
2
3x1.5 mm
) from the distribution board
(meter box) to the heat pump (see
additional information from
page 86).
■ The KM BUS wires are interchangea-
ble.
Handling
The max. permitted tilting angle for the
compressor during transportation and
installation is 45°.
8
!
Please note
Avoid appliance damage during
handling, particularly when trans-
porting the appliance off its pal-
let.
Never load the top, front or side
panels of the appliance.