Cooling control settings
Cooling
Parameter
■ 7100
Access
■ "Device settings"
■ "Programming"
■ "Cooling"
■ "Cooling"
■ l or m
Standard setting
Setting range
Cooling circuit
Parameter
■ 7101
Access
■ "Device settings"
■ "Programming"
■ "Cooling"
■ y to "Cooling circuit"
■ l or m
Standard setting
Setting range
Room temperature separate cooling circuit
Parameter
■ 7102
164
0
0 to 3
1
1 to 4
Determining the function of active cool-
ing.
Settings explained:
0 No cooling
1 NC-Box without mixer
2 NC-Box with mixer
3 AC-Box
Determining which circuit (heating circuit
or separate cooling circuit) cooling
affects.
Settings explained:
1 Cooling in heating circuit 1 (A1)
2 Cooling in the heating circuit 2 (M2)
3 Cooling in heating circuit 3 (M3)
4 Cooling in a separate cooling circuit