Heat pump for drying buildings

Parameter
■ 7300
This setting determines whether the heat
pump is used to dry the building as well
as the instantaneous heating water
heater.
Access
■ "Device settings"
■ "Programming"
■ "Internal hydraulics"
■ y to "HP for dry. building"
■ "YES" or "NO"
Screed program
Parameter
■ 7303
!
Please note
Risk of damage to building
through overheating screed at
high flow temperatures.
Prevent high flow temperatures
through a temperature limiter as
maximum limiter for underfloor
heating systems.
Note
Observe the specifications of
EN 1264-4. The report to be provided by
the heating contractor must contain the
following heat-up details:
■ Heat-up data with respective flow tem-
peratures
■ Max. flow temperature achieved
■ Operating condition and outside tem-
perature during handover
Control settings, hydraulics
This function must be set to "NO" if the
heat pump is not ready for operation
because the heat pump primary circuit is
not ready when building drying takes
place.
Standard setting
Setting range
■ The function continues after a power
failure or after the control unit has
been switched OFF.
■ The selected operating program con-
tinues, if the "Screed program" has
terminated in accordance with the pro-
gram or, before its expiry, the temper-
ature/time profile "0" is selected.
■ The temperature/time profiles 7 to 12
regulate to the maximum flow temper-
ature.
■ The screed program affects all ena-
bled heating circuits in parallel.
■ The set temperature is limited by
parameter "Max. flow temp." for the
heating circuit, even if the time profile
has been selected with a higher set
flow temperature.
No
Yes/No
153