Dhw Auxiliary Function - Viessmann Vitocal 300-G BW Installation And Service Instructions Manual

Compact heat pump with electric drive
Table of Contents

Advertisement

DHW auxiliary function

Parameter
■ 600B
Set DHW temperature 2
Parameter
■ 600C
Temp. sensor 2
Parameter
■ 600E
A second temperature sensor offers an
improved utilisation of the DHW cylinder.
It is fitted below the top temperature sen-
sor.
This temperature sensor (lower) is used
as stop criterion for the once-only DHW
heating through the demand "max. DHW
volume" or in the switching stages
"Standard" or "Set temp. 2".
DHW heating is started with the switch-
ing times stages using the upper tem-
perature sensor, in case of max. DHW
volume using the lower temperature
sensor.
Booster heater
Parameter
■ 6014
DHW control settings
Operating instructions
Operating instructions
Access
■ "Device settings"
■ "Programming"
■ "DHW"
■ y to"Temp. sensor 2"
■ "YES" or "NO"
Standard setting
Setting range
The DHW can be boosted either by an
electric booster heater (e.g. electric
immersion heater EHE) or by a second
heat source (control or enabling the
pump for the external heat source).
No
Yes/No
149