Ricoh MP C2504 Field Service Manual page 156

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

• Do not turn the power on until you perform "adjustment after installation," or it may not start
normally.
1.
Remove all the tapes and shipping retainers.
2.
Insert the two stud screws ([A] is the larger stud, [B] is the smaller stud).
3.
Mount the ARDF [A] by aligning the screw keyholes [B] of the ARDF support plate over
the stud screws.
4.
Slide the ARDF toward the front of the machine.
5.
Secure the ARDF with the two knob screws [C].
6.
Align the rear left corner of the platen sheet [A] with the corner [B] on the exposure glass.
7.
Close the ARDF.
ARDF DF3090 (D779)