Mitsubishi MELSEC iQ-F FX5 series Programming Manual page 809

Melsec iq-f fx5 series
Hide thumbs Also See for MELSEC iQ-F FX5 series:
Table of Contents

Advertisement

■Operation result
1.
Function without EN/ENO
The following table lists the operation results.
Operation result
No operation error occurred
An operation error occurred
2.
Function with EN/ENO
The following table lists the execution conditions and operation results.
Execution condition
EN
TRUE (Executes operation)
FALSE (Stops operation)
*1 When FALSE is output from ENO, data output from (d) is undefined. In that case, modify a program so that the data output from (d) is
not used.
Operation error
• (s1), (s2), and (s3) are INT or WORD
Error code
Description
(SD0/SD8067)
3405
The lower limit value specified by (s1) is greater than the upper limit value specified by (s2).
• (s1), (s2), and (s3) are DINT, DWORD, or TIME
Error code
Description
(SD0/SD8067)
3405
The lower limit value specified by (s1) is greater than the upper limit value specified by (s2).
• (s1), (s2), and (s3) are BOOL
Error code
Description
(SD0/SD8067)
3405
The lower limit value specified by (s1) is greater than the upper limit value specified by (s3).
• (s1), (s2), and (s3) are the REAL type
Error code
Description
(SD0/SD8067)
3402
The value of (s1) is outside the following range.
-126
|(s1)|<2
0, 2
The data specified by (s1) is -0, denormalized number, NaN (not a number), or .
The value of (s2) is outside the following range.
-126
|(s2)|<2
0, 2
The data specified by (s2) is -0, denormalized number, NaN (not a number), or .
The value of (s3) is outside the following range.
-126
|(s3)|<2
0, 2
The data specified by (s3) is -0, denormalized number, NaN (not a number), or .
3405
The lower limit value specified by (s1) is greater than the upper limit value specified by (s3).
• (s1), (s2), and (s3) are STRING
Error code
Description
(SD0/SD8067)
2820
"00H" is not set to a label specified by (s1), (s2), and (s3) or devices from specified device number to the end device number of
corresponding device.
3405
The lower limit value specified by (s1) is greater than the upper limit value specified by (s3).
The character strings specified by (s1), (s2), and (s3) have more than 16383 characters.
3406
The specified character string cannot be stored in a label specified by (d) or devices from specified device number to the end device
number of corresponding device.
Operation result
ENO
TRUE (Operation error did not occur)
FALSE (Operation error occurred)
*1
FALSE
128
128
128
(d)
Operation output value
Indefinite value
(d)
Operation output value
*1
Indefinite value
Indefinite value
20 SELECTION FUNCTIONS
20.3 Limit Control
20
807