Mitsubishi MELSEC iQ-F FX5 series Programming Manual page 45

Melsec iq-f fx5 series
Hide thumbs Also See for MELSEC iQ-F FX5 series:
Table of Contents

Advertisement

■Converting the operation result into a pulse
Instruction symbol
Description
MEP
Conversion of operation result to rising edge pulse
MEF
Conversion of operation result to falling edge pulse
Output instruction
■Out (excluding the timer, counter and annunciator)
Instruction symbol
Description
OUT
Device output
■Timer (low-speed, high-speed, low-speed retentive, high-speed retentive)
Instruction symbol
Description
OUT T
Low-speed timer
OUTH T
Timer
OUTHS T
High-speed timer
OUT ST
Low-speed retentive timer
OUTH ST
Retentive timer
OUTHS ST
High-speed retentive timer
■Counter, long counter
Instruction symbol
Description
OUT C
Counter
OUT LC
Long counter
■Annunciator
Instruction symbol
Description
OUT F
Annunciator
■Setting devices (excluding annunciator)
Instruction symbol
Description
SET
Sets devices
■Resetting devices (excluding annunciator)
Instruction symbol
Description
RST
Resets devices
■Setting/resetting annunciator
Instruction symbol
Description
SET F
Sets annunciator
RST F
Resets annunciator
ANS
Sets annunciator (with evaluation time)
ANR
Resets annunciator (smallest number reset)
ANRP
■Rising/falling edge output
Instruction symbol
Description
PLS
Generates a pulse for 1 cycle of a program at the rising edge of the input signal.
PLF
Generates a pulse for 1 cycle of a program at the falling edge of the input signal.
■Inverting the bit device output
Instruction symbol
Description
FF
Inversion of device output
ALT
ALTP
Reference
Page 107
Reference
Page 108
Reference
Page 109
Reference
Page 111
Page 112
Reference
Page 113
Reference
Page 114
Reference
Page 115
Reference
Page 116
Page 117
Page 118
Page 119
Reference
Page 120
Page 122
Reference
Page 123
Page 124
2 CPU MODULE INSTRUCTION
2.1 Sequence Instruction
2
43

Advertisement

Table of Contents
loading

Table of Contents