Function number 10
The measuring start and stop of the pulse density (rotation speed measurement) can be controlled for each channel of the
high-speed counter.
Bit position
b15
b14 b13 b12 b11
Function number 20
Set the value to turn on the bit of the high-speed comparison table number which is to be started or stopped.
Low-order bit position
b15
b14 b13
b12
b11
High-order bit position
b31
b30 b29 b28 b27 b26
Function number 30
For the multi-output high-speed comparison table, specification of a channel is not required. To start the multi-output high-
speed comparison table, set 01H in (s2). To stop it, set 01H in (s3).
Bit position
b15
b14 b13 b12 b11
Function numbers 40 and 50
The measuring start and stop of pulse width measurement and PWM can be controlled for each channel.
Bit position
b15
b14 b13 b12 b11
Precautions
• When the same channel is simultaneously turned on for start and stop, the stop operation is prioritized.
• When the high-speed comparison table is used with the DHIOEN instruction, the total number of high-speed comparisons,
including the DHSCS instruction, DHSCR instruction, DHSZ instruction, and interrupt input of built-in positioning, must be 4
or less.
• To start the multi-output high-speed comparison table (function number: 30), start the high-speed counter using the
(D)HIOEN instruction in advance.
• The high-speed input/output instructions operate according to the following parameters.
Function
Function specified by the DHIOEN instruction
number
0
High-speed counter
10
Pulse density (rotation speed measurement)
20
High-speed comparison table
30
Multi-output high-speed comparison table
40
Pulse width measurement
50
PWM
Operation error
Error code
Description
(SD0/SD8067)
1810
A channel number which is used in another instruction is specified.
3405
An invalid function number is specified in (s).
3600
A channel number which is not selected in the parameter setting is executed.
b10
b9
b8
b7
b6
b5
CH8
CH7
CH6
b10
b9
b8
b7
b6
b5
b25 b24
b23 b22 b21
b10
b9
b8
b7
b6
b5
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
CH5
CH4
CH3
CH2
CH1
b4
b3
b2
b1
b0
4
3
2
1
b20 b19
b18 b17 b16
b4
b3
b2
b1
b0
Valid
b4
b3
b2
b1
b0
CH4
CH3
CH2
CH1
Parameter setting
Channel setting of the high-speed counter
Channel setting of the pulse density/rotation speed measurement
High-speed counter
Output setting of the high-speed counter
Output setting of the high-speed counter