12
INVERTER COMMUNICATION INSTRUCTION
12.1

Inverter operation monitoring(Status check)

IVCK
This instruction reads the operation status of an inverter to the CPU module.
Ladder diagram
(s1)
(s2) (d1)
Setting data
■Descriptions, ranges, and data types
Operand
Description
(s1)
Inverter station number
(s2)
Inverter instruction codes
(d1)
Device number storing the read value
(n)
Channel to be used
(d2)
Head bit device to which the execution status of the instruction is output
*1  Refer to Serial communication manual or respective inverter manual.
■Applicable devices
Operand
Bit
X, Y, M, L,
U\G T, ST,
SM, F, B, SB
(s1)
(s2)
(d1)
(n)
(d2)
*1 T, ST, C cannot be used.
Processing details
The operation status corresponding to the instruction code specified in (s2) of an inverter connected to the channel to be used
(n) whose station number is specified in (s1) is read and transferred to (d1). For details, refer to  Serial communication
manual. (For the instruction codes, refer to the each inverter manual.)
Precautions
Three devices are occupied from the device specified in (d2). Make sure that these devices are not used in other controls.
Operation error
Error code
Description
(SD0/SD8067)
1810
Channel number specified by (d) is used by another instruction.
2820
The specified device exceeds the range of the corresponding device.
3405
The value specified by (s1) is other than any of K0 to 31.
The value specified by (n) is other than any of K1 to 4.
3600
Channel number specified by (d) is not set by parameters.
For communication errors, refer to  Serial communication manual.
(n)
(d2)
Word
T, ST, C, D,
U\G
C, LC
W, SD, SW, R
*1
*1
*1
Structured text
ENO:=IVCK(EN,s1,s2,n,d1,d2);
Range
Data type
K0 to 31
16-bit signed binary
*1
16-bit signed binary
16-bit signed binary
K1 to 4
16-bit unsigned binary
Bit
Double word Indirect
specification
Z
LC
LZ
12 INVERTER COMMUNICATION INSTRUCTION
12.1 Inverter operation monitoring(Status check)
Data type (label)
ANY16
ANY16
ANY16
ANY16_U
ANY_BOOL
Constant
Others
K, H
E
$
675
12