Precautions
The value specified in (s2) should only be the channel of high-speed counter number (1 to 8) set by the parameter. If a
channel which is not set by the parameter or a value other than K1 to K8 is specified, an operation error occurs.
For other precautions, refer to  User's manual [Application].
Operation error
Error code
Description
(SD0/SD8067)
3780
The DHSCS, DHSCR, and DHSZ instructions are used exceeding the maximum limit of the in number of these instructions.
3405
A channel number outside the range is specified.
3600
A channel number for which the channel setting is not set is specified in the operand in channel number specification of the high-speed
counter.