is less sensitive to an intruder walking directly towards it. Avoid pointing the PIR at
windows or heat sources as these may cause the PIR to operate incorrectly.
Reed switches should be installed across doors/windows where two surfaces open and
close. Place the detector on the frame and the magnet on the door/window. Take care
to close the door/window and note any gap between the magnet and the detector. If the
gap is large the detector will always be in an open state and prevent you from
arming/disarming the system. A plastic spacer can be used to ensure the reed switch
seals correctly.
Learning Detectors into ZeroWire
Example: Add a PIR motion detector to ZeroWire and assign it as zone 1.
1.
MENU
YOUR 4 TO 8 DIGIT INSTALLER CODE
2.
3.
PRESS DEVICE BUTTON
4.
1
5.
1
6.
MENU
Zones Guide
A zone (sometime referred to as a detector, sensor, or input) on the ZeroWire is a single
physical hardwired connection or a wireless connection. They can be configured as one of
many zone types that greatly increase the functionality of the ZeroWire system.
Additionally zones on the ZeroWire can be used as logic inputs within actions.
Zone Number
The ZeroWire can support a total of 64 zones. Each zone is identified by a unique zone
number, which cannot be altered, and remains as the key reference for each zone.
50
5
ENTER
1
ENTER
ENTER
MENU
MENU
Select Zone Configuration.
Enter your Installer code.
Select 1 to add detector.
Activate the detector learn-in sequence (see specific
wireless detector manual for instructions).
ZeroWire will announce that the detector or keyfob is
detected.
Assign the detector as zone number 1, or just press
Enter to automatically assign a number.
Press 1-6 for the zone type.
Exit from the menu.