Configuring Zone - Interlogix ZEROWIRE ZW-6404 Installation Manual

Wireless security & home automation
Table of Contents

Advertisement

Zone Type
The zone type can be changed using the ZeroWire keypad to one of the following defaults.
If you require further customization please use the ZeroWire Web Server, UltraSync + app,
or DLX900 to access more advanced settings.
Option
Voice
1
Delay Zone Type
2
Delay Zone Type with Bypass in Stay Mode
3
No Delay Zone Type
4
No Delay Zone Type with Bypass in Stay Mode
5
24 Hour Zone Type
6
24 Hour Silent Zone Type
Smoke Zones
Smoke Zone
Configuring Zone Names
All zones can be named using library words on page 106. This makes it easier to identify
the correct detector in the event of a condition. You may enter up to eight words to achieve
your desired description.
Example: Configure zone 1 name as "Dining Room Zone"
MENU
1.
YOUR 4 TO 8 DIGIT INSTALLER CODE
2.
3.
4.
1
5.
5
1
1
1
2
6.
MENU
If you do not require all eight words, just press MENU as in step 6 after you have entered
the last word number.
ZeroWire Installation Manual
6
ENTER
4
ENTER
3
ENTER
8
ENTER
2
ENTER
MENU
MENU
Zone Type
3 Entry Exit Delay 1
3 Entry Exit Delay 1
6 Instant
6 Instant
2 24 Hour Audible
7 24 Hour Silent
8 Fire Alarm
Select main menu - Option 6, Basic system
configuration.
Enter your Installer code.
Select zone name recording.
Select zone 1.
Select word "Dining" from the word library.
Select word "Room" from the word library.
Select word "Zone" from the word library.
Exit from the menu.
Zone Options
1 Bypass
2 Bypass Stay
1 Bypass
2 Bypass Stay
6 Panic
7 Silent Panic
5 Fire
51