Stripped length
250 ± 5
Velcro tape (19 mm wide)
Bundle fastener
Cable with film sheath: No. 6 (conductive copper tape) 1.5 windings. Ground wire
shortened to 25 mm and soldered onto conductive tape (1).
Stripped length = 600 mm ± 5 mm
Color
Pair
a-Wire
group
(Tip)
1
1
wht/blu
2
wht/ora
3
wht/grn
4
wht/brn
5
wht/gry
Figure 4-84
Stripping the Open-End Cable for the S
4-148
0
(1)
b-Wire
Color
Pair
(Ring)
group
2
6
blu/wht
7
ora/wht
8
grn/wht
9
brn/wht
10
gry/wht
patch panel
a-Wire
b-Wire
Color
(Tip)
(Ring)
group
red/blu
3
blu/red
red/ora
ora/red
red/grn
grn/red
red/brn
brn/red
red/gry
gry/red
4
Patch Panel
0
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Pair
a-Wire
b-Wire
(Tip)
(Ring)
11
blk/blu
blu/blk
12
blk/ora
ora/blk
13
blk/grn
grn/blk
14
blk/brn
brn/blk
15
blk/gry
gry/blk
16
yel/blu
blu/yel
P31003-H3550-S403-4-7620, 02/05