Upgrading HiPath 3000 to V5.0

The following information describes the measures that are needed to upgrade the hardware
and software.
It is not possible to upgrade HiPath 3550 to HiPath 3500 or HiPath 3350 to HiPath
>
3300. This would require replacing the complete system.
9.3.1

Hardware Upgrade

The following hardware requirements apply to HiPath 3000/5000 V5.0 and higher.
Contol Boards
If the control board necessary for operating HiPath 3000/5000 V5.0 and higher is not available,
a replacement must be performed.
System
HiPath 3800
CBSAP, S30810-Q2314-X and higher
HiPath 3750
CBCPR, S30810-Q2936-X-J2 and higher
HiPath 3700
HiPath 3550
CBCC, S30810-Q2935-A301 and higher
HiPath 3350
HiPath 3500
CBRC, S30810-Q2935-Z301 and higher
HiPath 3300
Note for upgrading from hardware < version 1.2:
>
If the following subboards are present, they must be replaced:
IMOD),
MMC
For Deutsche Telekom AG only: The CBCP board S30810-Q2935-B201 must be replaced by
a CBCC board S30810-Q2935-A301.
Multimedia card MMC
An
MMC
with 64 MB is required to run HiPath 3000/5000 V5.0 and higher.
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Control board necessary for HiPath 3000/5000 V5.0 and higher
(replaces the FMC),
Expanding and Upgrading HiPath 3000
Upgrading HiPath 3000 to V5.0
CMA/CMS
(replaces the CGM/CGMC).
exup.fm
IMODN
(replaces the
9-29