Guided Maintenance; Diagnosis Options; Recording Hipath 3000 Board Status; Central Control Boards - Siemens HiPath 3000 Service Manual

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

12.3

Guided Maintenance

12.3.1

Diagnosis Options

12.3.1.1

Recording HiPath 3000 Board Status

12.3.1.1.1

Central Control Boards

RUN LED
A RUN LED that displays the system's operating capacity is located on the central control
board.
Table 12-2
RUN LED - LED Status Meaning
RUN LED
Off
On
Off
On
Off
for 0.1 s
Flashing
0.5 s on/0.5 s off
Flashing
0.1 s on/0.1 s off
1
The flashing rhythm depends on the load. The higher the system load the slower the flashing rhythm.
Options available?
You can call up the following options using the HiPath 3000 Manager E:
CMA
CMS
LIM
IMODN
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
No power
Reset switch pressed briefly
Reset switch held down for more than 5 seconds (LED is extinguished
to acknowledge that a reload has begun)
System boot
Load operation: APS in SDRAM, loadware, and card data
Normal operating state (zero load)
MMC removed or defective
Guided Maintenance
Meaning
1
service.fm
Service
12-23