Figure 3-56 Ivmp8, Ivmp8R (S30122-Q7379-X100, -K7379-Z100) - Siemens HiPath 3000 Service Manual

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

Switches and LEDs
X3 = LAN
connector,
8-pin RJ45
jack
Figure 3-56
IVMP8, IVMP8R (S30122-Q7379-X100, -K7379-Z100) (not for U.S.)
Lockout switch settings
Pressed = free (default)
Not pressed = locked: existing connections remain active, new connections are locked.
The yellow LED lights up when all connections are ended and the board is effectively
locked.
The yellow LED flashes when a lockout request is entered (via lockout switch or soft-
ware) but at least one call is still active.
To reset the board to the default state, activate the lockout switch twice within the first 10 s of
board startup.
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
2
X4
10
Lockout switch
LED (green)
LED (yellow)
X3
2
X2
10
Boards for HiPath 3000
Peripheral Boards
50
X1 = con-
nection to
X1
CUP/
CUPR
2
boards.fm
3-121