4.2.6.4
Connecting Peripherals to the SIVAPAC Connector on the Backplane
The boards should be installed in the cabinets as described in Section 4.2.5.
Danger
7
Be sure to connect the main protective earthing terminal on all system cabinets to
the grounding point of the electrical building installation before connecting up the pe-
ripherals (for example, potential equalization bus).
The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
Use the CABLUs (prefabricated cabling units) that are listed in the following table to establish
the connection with the MDFU-E. Open-end cables must be used if an external patch panel is
being used. See also Section 4.2.7, "Using an External Main Distribution Frame or External
Patch Panel".
CABLUs and open-end cables for SIVAPAC connectors
If
Slot with
CABLUs for connection between backplane (SIVAPAC connector) and
SLCN
MDFU-E (splitting strip for 16 TW):
SLMA8
●
SLMO8
STMD3
●
TM2LP
1
TMC16
CABLU for connection between backplane (SIVAPAC connectors) and ex-
1
TMDID
ternal patch panel S30807-K6143-X (SIVAPAC socket terminal strip):
●
●
Open-end cable (24 TW) for connection between backplane (SIVAPAC con-
nector) and external patch panel:
●
●
●
●
●
4-56
C39195-A7267-A370: 3 m in length, short stripped length for MDFU-E
slots 11-21 (see Figure 4-36)
C39195-A7267-A371: 3 m in length, long stripped length for MDFU-E
slots 1-10 (see Figure 4-36)
S30267-Z333-A20: 2 m in length (refer to Figure 4-42)
S30267-Z333-A50: 5 m in length (refer to Figure 4-42)
S30267-Z196-A150: 15 m in length
S30267-Z196-A250: 25 m in length
S30267-Z196-A350: 35 m in length
S30267-Z196-A550: 55 m in length
S30267-Z196-A950: 95 m in length