2. Remove the filler panel from the power bay if necessary.
3. If you are replacing a failed power supply, remove the failed DC power supply.
4. Grasp the handle of the new power supply.
5. Push the new power supply partway into the bay, leaving the terminal block at the
6. Use a Phillips screwdriver to remove the screw that secures the plastic safety cover
7. Note the positions of the ground stud and of the positive and negative power inputs.
Routine Maintenance
Caution:
Save the power filler panel in case you need to operate the Ethernet Routing
Switch 8800/8600 chassis with a power supply removed.
side of the power supply exposed. See
page 70.
to the power supply and remove the cover. Set the cover aside; you will replace it
later.
See
Job aid: DC power supply input and ground stud location
Installing the 8004DC and 8005DC power supply
Job aid: Inserting the DC power supply
on
on page 71.
March 2011