Aop30 Diagnosis - Siemens SINAMICS G150 Operating Instructions Manual

Converter cabinet units 75 kw to 1500 kw
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

6.6.5.5

AOP30 diagnosis

Software/database version
You can use this menu to display the firmware and database versions.
The database version must be compatible with the drive software status (you can check this
in parameter r0018).
Battery status
In this menu, you can display the battery voltage numerically (in Volts) or as a bar display.
The battery ensures that the data in the database and the current time are retained.
When the battery voltage is represented as a percentage, a battery voltage of ≤ 2 V is equal
to 0%, and a voltage of ≥ 3 V to 100%.
The data is secure up to a battery voltage of 2 V.
● If the battery voltage is ≤ 2.45 V, the message "Replace battery" is displayed in the status
● If the battery voltage is ≤ 2.30 V, the system displays the following message: "Warning:
● If the battery voltage is ≤ 2 V, the system displays the following message: "Caution: The
● If the time and/or database are not available after the system has been switched off for a
For instructions on how to change the battery, see "Maintenance and servicing".
Keyboard test
In this screen, you can check that the keys are functioning properly. Keys that you press are
represented on a symbolic keyboard on the display. You can press the keys in any order you
wish. You cannot exit the screen (F4 – "back") until you have pressed each key at least
once.
Note
You can also exit the key test screen by pressing any key and keeping it pressed.
LED test
In this screen, you can check that the 4 LEDs are functioning properly.
Converter cabinet units
Operating Instructions, 03/2012, A5E03263466A
bar.
weak battery".
battery is dead".
prolonged period due to the voltage being too low, the loss is established by means of a
CRC check when the system is switched on again. This triggers a message instructing
the user to replace the battery and then load the database and/or set the time.