Prepare Wires
Make sure your wires are labeled. If necessary, find the "other
end" connection for each wire on your heating or air conditioning
equipment and note the label there
1 Fan out wires so that they are aligned with their terminals
2 Do not bunch wires in front of the mounting plate Feed any slack
back into the wall
If you have both RH
and RC connections,
you must set the RC/
RH Switch to OPEN If you do
not have both connections,
set the switch to CLOSED
Follow these guidelines for safe and secure wire connections:
• Use at least 2 6 in of wire for each of your connections to the
Thermostat
• If you do not have enough wire, splice additional wire to allow
enough slack
• Terminals accept wires from 16-22 awg
• Remove 1/8 in insulation from the tip of each wire
• Take care not to damage the labels for each wire
10
Vivint Element CT200 Installation Guide
!
CAUTION
Do not allow wires to touch
each other or other parts on
the thermostat
Wiring