Configuration Parameters Cont.
The thermostat will report ambient temperature changes for
temperature values greater than the upper bound. This field
must be between 0F and 124F By default, this value is 0F
(report all temperature changes)
11. Simple UI Mode Enable / Disable
If set to 0, Simple UI mode is disabled If set to 1, Simple UI mode
is enabled
12. Multicast Enable/Disable (8-bit)
If set to 0, Multicast is disabled If set to 1, Multicast is enabled
13. Main Display Selection
This configuration Param on the CT110 sets what information is
displayed in the main thermostat display area (the largest central
numbers on the display) The default values is to display the
Temperature (0x01) on the main numbers
14. Save Energy Mode Type
This configuration value is used to read/write what behavior Save
Energy Mode causes in the thermostat when the thermostat
enters Save Energy Mode
15. Fan Timer
This configuration is used to activate the fan with an automatic
shut-off timer.
16. Humidity Activation
This parameter is a pass-through All the logic is handled by the
thermostat based on the A terminal assignment
17. Temperature Calibration
This configuration is used to set the temperature offset of the
thermostat The valid values are from -6 to 6 Note: although
the thermostat UI can set calibrations in intervals of 0 5°F, this
parameter can only accept whole numbers
18. Display Units
This configuration is used to set units used by the device to
display temperature
48
Vivint Element CT200 Operation Guide