Radio Thermostat CT200 User Manual page 20

Vivint element
Table of Contents

Advertisement

6 Wire Heat/Cool
1 Connect the W wire to the W
terminal This connects the heat
2 Connect the Y wire to the Y
terminal This connects to the
cooling compressor
3 Disconnect the RC and RH
terminals by removing the
Jumper Wire
4 Connect the RH wire to the RH terminal and the RC wire to the RC
terminal This connects power
5 Connect the G wire to the G terminal This connects the fan
6 If available, connect the C wire to the C terminal
7. Go to "Connect Your Wires" on page 9.
Multi-stage Heat & Multi-Stage Cool
The CT200 can handle up to 2
stages of HEAT and 2 stages of
COOL
1 Connect the W and W2 wires to
the W and W2 terminals This
connects the stages of HEAT
2 Connect the Y and Y2 wires to
the Y and Y2 terminals This
connects the stages of COOL
3 Connect the RH or R wire to the RH terminal This connects the
power
4 Connect the G wire to the G terminal This connects the fan
5 If available, connect the C wire to the C terminal
6. Go to "Connect Your Wires" on page 9.
20
Vivint Element CT200 Installation Guide
POWER
C B O W
THERMOSTAT TERMINALS
POWER
C B O W
THERMOSTAT TERMINALS
Wiring Diagrams
HVAC SYSTEM
C
W
Y R
R
H
W
Y Y
R
RC G A
2
2
H
*R
and R
disconnected
C
H
HVAC SYSTEM
W
Y Y
C
W
2
2
W
Y Y
R
RC G A
2
2
H
G
C
R
G