COMFORT
Comfort settings enable you to control:
Offsets the unit's temperature display
Calibration:
This feature enables you to set the acceptable variance in
Cycling:
temperature between the Thermostat's setting and the
current room temperature before the heating or cooling
system will turn on The Cycling range can be from 0 5
to 4 0F ( 25 to 2C) For example, if Cycling is set to 2 0°F
and the Thermostat is set to 70°F target temperature, the
heat cycle will start when the room temperature drops to
68°F Similarly, the cooling system will start when the room
temperature increases to 72°F The HVAC runs until the
room reaches the target temperature, and then shuts off.
Used for multiple stage systems only Staging is the number
Staging:
of degrees between the room temperature and the target
temperature at which the next stage in multi-stage systems
will engage to bring the room temperature back to the
target The default is 2°F The programmable range is 2°F
to 6°F (1°- 3°C)
Calibration
1 From the Home screen, press and hold the SIDE button for three
(3) seconds
2 Press DOWN to highlight Installer, then press the SIDE button
3 Press DOWN to highlight Comfort, then press the SIDE button
4 Press DOWN to highlight Calibration, then press the SIDE button
The current temperature offset displays.
5 Press UP or DOWN to change the value, then press the SIDE
button to confirm.
Cycling
1 From the Home screen, press and hold the SIDE button for three
(3) seconds
2 Press DOWN to highlight Installer, then press the SIDE button
3 Press DOWN to highlight Comfort, then press the SIDE button
4 Press DOWN to highlight Cycling, then press the SIDE button The
current cycling value displays
5 Press UP or DOWN to change the value, then press the SIDE
button to confirm.