Radio Thermostat CT200 User Manual page 21

Vivint element
Table of Contents

Advertisement

4 Wire Heat Pump (heat/cool)
without Auxiliary Heat
1 Connect the O wire to the O
terminal or the B wire to the
B terminal This connects the
change-over valve If you have
both O and B, connect only the
O wire to the O terminal and DO
NOT connect B to B terminal (see the Wire Reference Table on
page 23 for Trane terminal labels)
2 Connect the Y wire to the Y terminal This connects the
compressor
3 Connect the R wire to the RH terminal This connects the power
4 Connect the G wire to the G terminal This connects the fan
5 If available, connect the C wire to the C terminal
6. Go to "Connect Your Wires" on page 9.
Multi-stage Heat Pump with
Multi-Stage Aux Heat
The CT200 can handle up to 2
stages of Pump compression and 2
stages of AUX heat
1 Connect O wire to the O terminal
or the B wire to the B terminal
This connects the change-over
valve If you have both O and B,
connect only the O wire to the O terminal and DO NOT connect
B to B terminal (see Wire Reference Table on page X for Trane
terminal labels )
2 Connect the AUX 1 and AUX 2 wires to the AUX 1 and AUX 2
terminals This connects the auxiliary heat
3 Connect the Y and Y2 wires to the Y and Y2 terminals This
connects the compressor
4 Connect the R wire to RH terminal This connects the power
5 Connect the G wire to the G terminal This connects the fan
6 If available, connect the C wire to the C terminal
7. Go to "Connect Your Wires" on page 9.
Vivint Element CT200 Installation Guide
POWER
or
C B O W
THERMOSTAT TERMINALS
HVAC SYSTEM
C
B
O
POWER
or
or
C B O W
THERMOSTAT TERMINALS
Wiring Diagrams
HVAC SYSTEM
C
B
O
Y
R
or
W
Y Y
R
RC G A
2
2
H
AUX1
AUX2
Y
Y
R
2
W
Y Y
R
RC G A
2
2
H
G
G
21