Configuration Parameters Cont.
• Scale (2-bits)
The scale field indicates the temperature scale used: 0
indicates Celsius and 1 indicates Fahrenheit
• Bound Size (3-bits)
The size field indicates the number of bytes used for the
temperature filter value. This field must be one (0x01).
• Temperature Filter Lower Bound (8-bit)
The thermostat will report ambient temperature changes for
temperature values less than the lower bound. This field must
be between 0F and 124F By default, this value is 124F (report
all temperature changes)
• Temperature Filter Upper Bound (8-bit)
The thermostat will report ambient temperature changes for
temperature values greater than the upper bound. This field
must be between 0F and 124F By default, this value is 0F
(report all temperature changes)
Thermostat Reporting Filter Report Command Definition
7
6
Command Class = COMMAND_CLASS_CONFIGURATION
Precision (0x00)
• Parameter (8-bit)
The parameter is set to 10 (0x0A) for the temperature
reporting filter.
• Temperature Filter Lower Bound (8-bit)
The thermostat will report ambient temperature changes for
temperature values less than the lower bound. This field must
be between 0F and 124F By default, this value is 124F (report
all temperature changes)
• Temperature Filter Upper Bound (8-bit)
Vivint Element CT200 Operation Guide
5
4
Command = CONFIGURATION_SET
Parameter = 0x0A
Scale
Temperature Filter Lower Bound
Temperature Filter Upper Bound
3
2
Bound Size (0x01)
Z-Wave
®
1
0
47