Command
Stream Files via Telnet, RS-232, or USB
Load file to user flash
memory
24, 28
Load file to user flash
and set specific time and
date
24, 28
E
+ UF{filesize}*{day of week}•{month}•{day}• {year}•{hours}•{minutes}•{seconds},{filename}
Retrieve files from user
flash memory
24, 28
Backup or Restore Device Configuration
Save unit configuration to
a file system
Restore device
configuration
Port Assignment
Notes:
Duplicate port number assignments are not permitted (that is, the Telnet and web port numbers cannot be the same)
and result in an E13 error message.
Remapping of ports other than to reset them to defaults (23 or 80) or disabling them (setting to 0) must be to port
numbers equal to or greater than 1024.
Set Telnet port map
24
Reset Telnet port map
24
Disable Telnet port
24
View Telnet port map
24
Set web port map
24
Reset web port
24
24
Disable web port
View web port map
24
Set SNMP port map
24
Reset SNMP port map
24
24
Disable SNMP port
View SNMP port map
24
ASCII Command
Response
(Host to Scaler)
(Scaler to Host)
E
+ UF {filesize}, {filename}
Upl
See below.
Upl
E
}
Responds with 4 bytes of file
{filename} SF
size + raw unprocessed data
in file.
E
}
1 * {config type} XF
Cfg 1 * {config type}
E
}
0 * {config type} XF
Cfg 0 * {config type}
E
}
{port#} MT
Pmt {port number}
E
}
23 MT
Pmt 00023
E
}
0 MT
Pmt 00000
E
}
MT
{port#}
E
}
{port#} MH
Pmh {port number}
E
}
80 MH
Pmt 00080
E
}
0 MH
Pmh 00000
E
}
MH
{port#}
E
}
A {port#} PMAP
Pmap A(port number}
E
}
A 0 161 PMAP
Pmap A 00161
E
}
A 161 PMAP
Pmap A 00000
E
}
{port#}
A PMAP
DSC HD-HD 4K Plus A Series • Remote Configuration and Control
Additional Description
}
]
If there is insufficient space on
]
the unit to store the sent file, the
response is Fld
Save the current configuration to
a {config type} file.
]
]
Restore a configuration file to
the unit.
Set Telnet port number.
]
Reset the Telnet port number to
]
the default (23).
]
Disable the Telnet port.
View the current Telnet port
]
selection.
]
Set the web port number.
Reset the web port number to
]
the default (80).
]
Disable the web port.
View the current web port
]
selection.
]
Set the SNMP port number.
Reset the SNMP port number to
]
the default (161).
]
Disable the SNMP port.
View the current SNMP port
]
selection.
]