Self-Test Results

7984-A2-GB20-10
The results of the last power-up or reset self-test appear in the middle column of
the System and Test Status screen.
Table 4-2. Self-Test Results Messages
Message
What Message Indicates
CPU Failed
The CPU failed internal testing.
Device
One or more of the Unit's integrated
Failed
circuit chips failed device-level
testing.
DSX-1
The Unit failed to loop data on the
Failed, Pt 1
DSX-1 interface on Port 1.
Memory
The 7984 Standalone Termination
Failed
Unit failed memory verification.
FPGA
A failure in the FPGA was detected.
Failed, Pt1
DataPath
The unit failed to loop data between
Failed, Pt1
the DSX-1 Port and the DSL loop.
Failure
An internal failure occurred.
xxxxxxxx
(xxxxxxxx represents an 8-digit
hexadecimal failure code for use by
service personnel.)
Passed
No errors were detected.
February 1999
Monitoring the Unit
What To Do
1. Reset the unit and try again.
2. Call your service
representative for assistance.
1. Reset the unit and try again.
2. Call your service
2. Call your service
representative for assistance.
1. Reset the unit and try again.
2. Call your service
representative for assistance.
1. Reset the unit and try again.
2. Call your service
representative for assistance.
Record the failure code and
contact your service
representative.