Configuring the Unit Using the Internal Switches

496-15104
7984-A2-GB20-10
Use internal Switchpacks S1 and S2 to manually configure the unit. Use
Figure 3-1
to locate Switchpacks S1 and S2.
!
HANDLING PRECAUTIONS FOR
STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from damage
due to electrostatic discharge (ESD) during normal operation. When
performing installation procedures, however, take proper static control
precautions to prevent damage to equipment. If you are not sure of the
proper static control precautions, contact your nearest sales or service
representative.
Procedure
To configure the unit using internal Switchpacks S1 and S2:
1. Power down the unit and remove the enclosure cover, exposing the circuit
board.
2. Locate Switchpack S1 using
3. Set Switch 1 on Switchpack S1 to ON to enable Switchpacks 1 and 2.
4. After you enable the switchpacks, you must set the switches to your desired
configuration. Refer to
5. Replace and secure the cover.
6. Power up the board to reset and enable the new configuration.