Linkup And Linkdown - Paradyne HOTWIREt 7984 User Manual

M/hdsl standalone termination unit with dsx-1 interface
Hide thumbs Also See for HOTWIREt 7984:
Table of Contents

Advertisement

Standards Compliance for SNMP Traps

linkUp and linkDown

B-2
The link SNMP traps are:
linkUp – The unit recognizes that one of the communication interfaces is
operational.
linkDown – The unit recognizes that one of the communication interfaces is
not operational.
The network and synchronous port interfaces (physical sublayer) are represented
by an entry in the MIB-II interfaces table and supported by the DS1 MIB.
The following list describes the conditions that define linkUp and linkDown:
linkUp/Down Variable-Bindings
ifIndex (RFC 1573)
This object provides the index into the ifTable and potentially into tables in other MIBs.
The values of ifIndex are the same for all models, although not all indexes are
supported for each model.
The ifIndex included with the trap consists of:
– 1
COM Port
– 2
HDSL Network Interface, Port 1
– 6
DSX-1 Interface, Port 1
ifAdminStatus (RFC 1573)
This object specifies the operational state of the interface:
– up(1)
HDSL Network: DSL link is established.
DSX-1: No alarm condition exists.
– down(2)
HDSL Network: DSL link is not established.
DSX-1: An alarm condition exists.
– testing(3)
A test is active on the interface.
ifOperStatus (RFC 1573)
This object contains the same value as ifAdminStatus.
i
fType (RFC 1573)
This object is the type of interface:
– T1(19)
Used for the DSX-1 interface.
February 1999
7984-A2-GB20-10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hotwire 7984

Table of Contents