Ending An Active Test - Paradyne HOTWIREt 7984 User Manual

M/hdsl standalone termination unit with dsx-1 interface
Hide thumbs Also See for HOTWIREt 7984:
Table of Contents

Advertisement

Ending an Active Test

Telco-Initiated Tests
Telco-Initiated Line Loopback
7984-A2-GB20-10
A test initiated by the user can be ended by the user. Tests can also be
terminated automatically by enabling the Test Timeout option from the System
Options Menu.
A Test Timeout option is available to automatically terminate a Loopback or
Pattern test (as opposed to manually terminating a test) after it has been
running a specified period of time. The default is 10 minutes.
Refer to Table A-3,
System
On each test screen is a Command column. To stop the test, press Enter
when the cursor is on the Stop command.
Use the Abort Tests selection from the Test menu to stop all tests running on
all interfaces, with the exception of network-initiated loopbacks. Command
Complete appears when all tests on all interfaces have been terminated.
An aborted test may continue to run for a few seconds as the abort command
is sent to the remote end and processed.
The Hotwire 7984 Standalone Termination Unit supports Telco-initiated tests as
shown in the following table.
Activation and
Deactivation
Line Loopback
In-Band Signal
Supported
Bit-Oriented
Supported
Message-Oriented
Not Applicable
The Hotwire 7984 Standalone Termination Unit supports line loopback as
specified in AT&T TR 54016, AT&T TR 62411, and ANSI T1.403. A Telco-initiated
line loopback loops the received signal on the DSX-1 interface back to the DSX-1
interface without modification. Framing, CRC, and FDL bits are returned
unaltered, and no BPVs or other line coding errors are removed.
CAP
DSL
All Ones
Port
Transceiver
February 1999
Options.
Payload Loopback
Not Applicable
Supported
Not Supported
CAP
T1
LIU
Framer
Framer
Testing
Remote Line
Loopback
Not Supported
Supported
Not Applicable
DSX-1
Telco
Port
99-16252