MIC IP starlight 7000 HD
Video transmission
If the unit is operated behind a firewall, select TCP (HTTP port) as the transfer protocol. For
use in a local network, select UDP.
Notice!
Multicast operation is only possible with the UDP protocol. The TCP protocol does not
support multicast connections. The MTU value in UDP mode is 1,514 bytes.
TCP rate control
Select On to control the rate of transmission control protocol. Select Off if you do not want to
control the TCP rate.
HTTP browser port
Select a different HTTP browser port from the list if required. The default HTTP port is 80. If
you want to allow only secure connections via HTTPS, you must deactivate the HTTP port. In
this case, select Off.
HTTPS browser port
If you wish to allow browser access on the network via a secure connection, select an HTTPS
browser port from the list if necessary. The default HTTPS port is 443. Select the Off option to
deactivate HTTPS ports; only unsecured connections will now be possible.
The camera uses the TLS 1.0 encryption protocol. You may have to activate this protocol via
your browser configuration. You must also activate the protocol for the Java applications (via
the Java control panel in the Windows control panel).
Notice!
If you want to allow only secure connections with SSL encryption, you must select the Off
option for each of the parameters HTTP browser port, RCP+ port 1756 and Telnet support.
This deactivates all unsecured connections. Connections will then only be possible via the
HTTPS port.
You can activate and configure encryption of the media data (video and metadata) on the
Encryption page (see Encryption).
HSTS
Select this option to use the web security policy HTTP Strict Transport Security (HSTS) to
provide secure connections.
RCP+ port 1756
To exchange connection data, you can activate the unsecured RCP+ port 1756. If you want
connection data to be transmitted only when encrypted, select the Off option to deactivate
the port.
Telnet support
If you want to allow only secure connections with encrypted data transmission, you must
select the Off option to deactivate Telnet support. The unit will then no longer be accessible
using the Telnet protocol.
Interface mode ETH
Select the Ethernet link type for the ETH interface.
Options are:
Bosch Security Systems
Auto
10 Mbps HD (half duplex)
10 Mbps FD (full duplex)
100 Mbps HD (half duplex)
Operation Manual
Network | en
85
2016.07 | 5.0 | F.01U.291.520