"High Shock Event" appears in
English in the middle of the OSD until
the camera is reset.
Bosch Security Systems
The camera experienced a high shock event.
Check the integrity of the mechanical parts and
the screws (especially on the yoke arms).
If there is obvious and severe damage, stop using
the camera and contact your Bosch Service
Center for assistance.
If no damage is evident, complete one of the
following steps:
a) Cycle the power on the camera.
b) Send command AUX OFF 65 to remove the
OSD message.
If IVA is configured on your camera, the OSD
message may interfere with IVA operation.